Air Blown Fiber Unit (ABF) Fiber Units/Bundles-FU

Air Blown Fiber Unit (ABF) Fiber Units/Bundles-FU
Air Blown Fiber Unit (ABF) Fiber Units/Bundles-FUAir Blown Fiber Unit (ABF) Fiber Units/Bundles-FUAir Blown Fiber Unit (ABF) Fiber Units/Bundles-FU
产品目录定制光缆
品牌RUX
产品规格ABF
Fiber TypeG652D,G657A1,G657A2
Fiber Count1-12cores
OEMAvailable
支付方式L/C, Western Union, T/T
文档下载pdf icon
更新时间2024/4/26
详细信息

Features anBenefits(Air Blown Fiber Unit

1. 2468 and 12 fibres options.

2.  Stable  structure, good mechanical  and  temperaturperformance.

3. Designed  with  special  grooves  to  advance blowing distance

4. Lightweight and properstiffness , repeat installation.

5.  Designed with no gel, easy stripping and handling.

6. Better costs advantage compared to traditional product.

7.  Complete accessories, less manpower, lower installation time.


Technical Parameter

 Fibre Unit Structure


 Basic Performance

Fibre Count

 

2 Fibres

 

4 Fibres

 

6 Fibres

 

8 Fibres

 

12 Fibres

Outer Diameter

(mm)

1.15士0.05

1.15士0.05

1.35士0.05

1.50士0.05

1.65士0.05

Weight

(g/m)

1.0

1.0

1.3

1.8

2.2

Min Bend radius        (mm)

Dynamic: 20 times of cable diameter; Static: 10 times of cable diameter

 

Temperature

Storage:-30C � +70C      Operation:-30C � +70C      Installation:-5C � +50C

 

Cable service life   (estimate value)

 

25 years

Note: It is recommended that thstructurof 2 fibres unit consisof 2 filled fibres, for it is proved that 2 fibres uniwith 2filled fibres        is better than the onwith zero or one filled fibrithe blowing performancand thfibrstripping-ability


 Blowing Test


Fibre Count

 

2 Fibres

 

4 Fibres

 

6 Fibres

 

8 Fibres

 

12 Fibres

 

Test equipment

PLUMETTAZ:UM25,

ERICSSON:F,

CATWAY:FBT-1.1

 

Standarduct

 

5.0/3.5 mm

 

Pressure

 

7bar / 10bar

 

Typical blowing distance

 

500m / 1000 m

 

500m / 1000m

 

500m / 1000m

 

500m / 1000m

 

500m / 800m

 

Typical blowing time

 

10 min / 18 min

 

10 min / 18 min

 

12 min / 18 min

 

13 min / 18 min

 

15 min / 20 min



  MechanicalPerformance

  

 

Test

 

Standard

 

Parameters

 

Test Results

 

Tension

EN 18700 A1/501

 

IEC 60794-1-2-E1

 

Load is 1xW

 

Additional attenuation ::0.05dB after test

 

Bend

 

IEC 60794-1-2--E11A

Diam 40mmx3turns

5 cycles a20C

 

Additional attenuation ::0.05dB,after test

 

Crush

 

IEC 60794-1-2-E3

 

100 N, 60s

 

Additional attenuation ::0.05dB,after test

All optical testing proceeded at 1550 nm


  
Environment Performance

 


 

Test

 

Standard

 

Parameters

 

Test Results

 

Temperature Cycle

 

IEC 60794-1-2-F1

-300C+700C,

 

(2 cycles)

Absolute attenuation ::0.5dB/km,during test

 

Additional attenuation ::0.1dB/km, during and aftertest

 

WateSoak

 

IEC 60794-5

1000 hours in water, 18C�22C

(Test after temcycle) ::0.07dB/km

 

Change comparetstart value

 

DamHeat Cycle

 

IEC 60068-2-38

250C, 650C, 250C,650C,

 

250C,-100C, 250C

Absolute attenuation ::0.5dB/km,during test

 

Additional attenuation ::0.1dB/km, during and aftertest

Alopticatestinproceeded at 1550 nm


 

  Fibre Color Code    (Fibre colorcan also be determined by customer)


NO.

1

2

3

4

5

6

7

8

9

10

11

12

Color

Blue

Orange

Green

Brown

Grey

White

Red

Black

Yellow

Violet

Pink

Aqua














 

  Sheath Color: Yellow/ Green/ Natural/ Customized

 

 SheathMarking

 Thoutesheathimarkedinmeteintervals as follows:

RUX  ABF  typeoffibreandnumber   [MM-YYYY] =lengthmarkinginmeter= Example:  RUX  ABF  G652D 4F [04- 2014] =1888m=

 

  Delivery Length

 Standardelivery lengthare1000m, 2000m, 3000m4000m,6000with tolerancof   -0.5+1%Fomoreoptions, pleascontacthecustomer service.

 


 


给我发送求购信息
*Email
电话
*标题
*内容
上传
  • 仅支持.rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf,最大20M
  Sophie
  Nico
  Alicia
  Wendy